Quick answer
Start with 12 consecutive months of electricity consumption in kilowatt-hours (kWh). For a preliminary sizing discussion, divide the annual energy you want solar to produce by an address-specific estimate of annual production per installed kilowatt. That gives a starting capacity in kilowatts DC (kW DC)—not a finished design. Roof conditions, shading, future electricity use and utility billing rules still need checking. PVWatts explicitly describes its estimates as suitable for preliminary studies, with final design decisions left to qualified professionals. (consumersenergy.com)
This guide is for U.S. homeowners considering grid-connected residential solar. The worked examples are hypothetical planning exercises, not local production forecasts or installation recommendations.
1. Gather a full year of kWh—not just bill amounts
Your first task is to establish an annual electricity baseline. Consumers Energy’s published planning guidance describes the basic method: total 12 months of electricity use from your bills. Use that arithmetic without assuming its Michigan program rules apply elsewhere. (consumersenergy.com)
Create a spreadsheet with these columns:
| Record | What to enter |
|---|---|
| Billing period | Start and end dates |
| Electricity consumed | kWh for that period |
| Billing days | To identify unusually long or short periods |
| Context | Vacations, new equipment, occupancy changes or unusual weather |
| Data quality | Any estimated readings or missing periods |
Use consecutive periods without gaps or overlaps. Keep dollar charges in a separate column; the sizing calculation needs energy consumption, not the amount paid.
Check that your total covers approximately one year. If you recently moved in, label the available history clearly rather than multiplying one convenient month by 12 and treating the result as established consumption.
Ask the installer: “Which dates and annual kWh total did you use, and how did you handle incomplete or unusual periods?”
That question establishes a shared baseline before competing proposals introduce different forecasts.
2. Keep seasonal and hourly patterns visible
Do not discard the monthly figures after calculating the annual total. They are useful for comparing consumption with an installer’s monthly production estimate. Utility tools may also show how weather affects use: PG&E, for example, provides usage views by bill, month and hour, along with weather comparisons. Other utilities’ tools and available intervals differ. (pge.com)
Request your utility’s downloadable usage file if available. PG&E’s published instructions describe a Green Button export for a selected date range or billing period; check your own provider’s process rather than assuming the same menus apply. (help.pge.com)
Use the records to ask:
- Which months account for the largest share of consumption?
- Is electricity use concentrated during daylight, evenings or overnight?
- Does the year include a major change that should not be repeated in the forecast?
- Can the installer compare monthly consumption and production on the same chart?
An annual energy match is not an hour-by-hour match. A grid-connected system can export surplus electricity during some periods and require grid electricity during others. (consumersenergy.com)
Do not fabricate an hourly profile from monthly totals. If interval records are unavailable, ask the installer to label any assumed household usage pattern.
3. Separate current consumption from future changes
Build two forecasts: the home as it operates today and the home after specific planned changes. Keep speculative purchases outside the main case.
For an electric vehicle, document expected home charging rather than assigning all driving electricity to the house. DOE notes that charging a plug-in vehicle adds electricity demand. Ask the installer to show the assumed mileage, vehicle consumption, charging losses, home-charging share and charging schedule separately. (energy.gov)
A planned heat pump needs a different discussion. Request an electricity-use estimate from the HVAC contractor, including seasonal demand and how much heating an existing system will continue to provide. Technical guidance hosted by DOE explains that estimating a partial heat-pump system requires accounting for the share of heating served by the secondary system and the equipment’s performance. (bsesc.energy.gov)
Also list efficiency work that could reduce future demand. A professional home energy assessment can help identify and prioritize improvements; do not subtract an arbitrary savings percentage from your bills. (energy.gov)
A useful planning ledger is:
Forecast annual kWh = historical annual kWh + supported additions − supported reductions
Attach a source, expected completion date and uncertainty note to each adjustment. Ask for a separate scenario when a major change remains undecided.
4. Convert annual kWh into a preliminary capacity
Three quantities must stay separate:
- kWh: energy consumed or produced over time.
- kW DC: the solar array’s rated direct-current capacity.
- Annual production per kW DC: modeled annual AC electricity divided by installed DC capacity.
The array’s DC rating is measured under standard test conditions; it is not a promise of continuous household output. (consumersenergy.com)
Use this planning calculation:
Preliminary kW DC = target annual solar production in kWh ÷ modeled annual kWh per kW DC
For illustration only, suppose a household uses 10,800 kWh annually and wants to investigate producing an equivalent annual amount. Assume a site-specific forecast of 1,350 kWh per installed kW DC per year:
10,800 ÷ 1,350 = 8.0 kW DC
If a different roof layout instead yields an assumed 1,100 kWh per kW DC annually:
10,800 ÷ 1,100 ≈ 9.8 kW DC
These are hypothetical inputs, not national benchmarks. The calculation shows why the same electricity history can lead to different capacity estimates.
PVWatts estimates monthly and annual generation using location and system inputs. Ask for the production report supporting the denominator—not just a salesperson’s customary “kWh per panel” figure. (pvwatts.nlr.gov)
5. Compare two households with the same annual use
Consider two hypothetical homes in the same U.S. utility territory. Both consume 10,800 kWh per year, and neither example includes a battery.
| Planning detail | Household A | Household B |
|---|---|---|
| Usage pattern | Substantial daytime consumption | Most consumption after sunset |
| Roof conditions | Broad, relatively unshaded roof plane | Smaller usable areas with shading |
| Assumed annual production per kW DC | 1,350 kWh | 1,100 kWh |
| Capacity suggested by annual-energy arithmetic | 8.0 kW DC | About 9.8 kW DC |
| Hypothetical site-assessed roof limit | Enough for the proposed layout | Only 7.0 kW DC |
Under these assumptions, Household B’s roof-limited system would produce:
7.0 × 1,100 = 7,700 kWh per year
That equals roughly 71% of its annual consumption. It does not mean 71% bill savings or 71% independence from the grid.
The practical inference is that Household B should compare a feasible smaller system—not keep adding panels on paper until the annual totals match. ENERGY STAR identifies roof direction, pitch and shading as factors affecting production. (energystar.gov)
The households also need separate financial models. Their timing of consumption could change how much generation is used directly or exported. Where exports receive less than the purchase price, equal annual generation does not necessarily have equal value. This is a scenario implication, not a savings prediction for either household. (pvwatts.nlr.gov)

6. Check what the roof and production model actually assume
Request a roof layout showing the proposed panel locations, capacity on each roof plane, orientation and tilt. Ask which areas were excluded and why.
Roof age and condition belong in this conversation too. ENERGY STAR recommends addressing necessary roof renovations before solar to avoid later panel removal and reinstallation. Leave roof access, structural evaluation and electrical assessment to qualified professionals. (energystar.gov)
For the production model, ask how the installer handled:
- Trees, chimneys and nearby buildings.
- Shading differences between roof planes.
- Soiling and snow, where relevant.
- Inverter sizing and conversion efficiency.
- Other modeled losses and equipment assumptions. (samrepo.nlr.gov)
Do not accept an unexplained default loss allowance as proof that the site’s shading has been assessed. PVWatts warns that default-loss results may be optimistic under conditions including shading and higher soiling or snow losses. Its weather-based outputs also represent typical or long-term conditions, not guaranteed production for a particular future year. (pvwatts.nlr.gov)
Use an independent preliminary model as a question generator. If its output differs from the proposal, compare assumptions before deciding which number is more credible.

7. Request a written sizing-assumptions sheet
Send every bidder the same consumption records and future-use ledger. Then request the following in writing:
- Baseline: Billing dates, annual kWh and treatment of unusual periods.
- Future demand: Each addition or reduction, its evidence and expected timing.
- Objective: Annual energy target, bill-reduction objective or another stated goal.
- Capacity: Proposed kW DC, panel count and inverter AC rating.
- Layout: Capacity, direction, tilt and shading treatment for each roof plane.
- Model: Software/version, weather dataset and site location used.
- Forecast: Monthly and annual AC generation, with loss assumptions.
- Billing: Applicable utility tariff, export treatment and assumed usage timing.
- Uncertainty: What remains unverified and what could change after the site assessment.
This is a proposed comparison worksheet, not a required industry form. Its purpose is to make differences visible.
For equipment and modeling entries, distinguish DC array capacity from AC inverter capacity and modeled energy production; these are separate quantities in the modeling documentation. (samrepo.nlr.gov)
Also request two explanations: “Why this size rather than a smaller system?” and “What limits a larger system?” A useful answer should identify the relevant constraint rather than simply repeat the annual consumption total.
8. Catch the mistakes before choosing a size
Use these final checks before accepting a sizing recommendation:
One month became the whole year. Rebuild the baseline from consecutive records and retain the monthly breakdown.
Future equipment was counted twice. Check whether an EV or heat pump already appears in the historical bills before adding its full forecast again.
Different bidders used different households. Reconcile occupancy, future purchases and consumption assumptions before comparing their proposed capacities.
A roof constraint disappeared from the forecast. Confirm that the modeled capacity matches the actual proposed layout.
“100% offset” became “no electricity bill.” Ask whether offset means annual kWh, modeled bill reduction or something else. Export compensation can differ from the price of purchased electricity. (energystar.gov)
A preliminary estimate became a guarantee. Keep modeled production separate from any contractual commitment. PVWatts advises professional assessment and more detailed analysis for final design decisions. (pvwatts.nlr.gov)
Your immediate goal is not to identify a perfect panel count yourself. It is to give installers a defensible consumption baseline—and require them to explain how the home, roof and utility rules turn that baseline into a proposed system.